Applications

Five industries where cure chemistry decides yield.

The same addition-cure chemistry behaves differently in a thin release coating and a thick potting section. Each application page below states the failure mode, the grades most often specified, the process window and the measured outcome behind the recommendation — with the test conditions that produced it.

Application map

One range, five different failure modes.

Every page in this section is built the same way: the defect that stops the line, the grades selected for it, the process window to trial them in, and the measured result that supports the recommendation. Start with the industry that looks like your process.

Comparison

Shortlist by industry, then open the data.

The table is a shortlist, not a specification. It pairs the most common failure in each industry with the grades most often specified and the first headline metric from that application page. Dosage, inhibitor pairing and process windows are stated in full on the application page.

IndustryTypical failureRecommended gradesHeadline metric
PPF & CoatingsFilm yellows and hazes after months of sun exposure and engine-bay heat radiationPC-42 · PC-50 · PC-51ΔE 0.8
after 85°C / 48 h vs 4.2 conventional
Release LinersLine speed is capped by how fast the silicone can cross-link, not by the coaterPC-11 · PC-12 · PC-13 · PC-14 · PC-15 · PC-16≤ 0.2 μm
surface roughness, MLCC release film
Optical & ElectronicsCatalyst is insoluble in high-RI systems and clouds the compoundGZ-5 · PC-42 · PC-1699.82%
light transmittance, Mini LED encapsulation
LSR Medical/FoodPeroxide systems release by-products that fail medical and food-contact reviewPC-42 · PC-12 · PC-51YI ≤ 1.5
after 100 × 121°C wet-heat sterilisation
EncapsulationSulfur, phosphorus, nitrogen and heavy-metal traces on boards and housings poison the catalystPC-18B · PC-18A · PC-50S · P · N
target contaminant families

Headline metrics are quoted from the application data with their measurement conditions. No figure on this page is extrapolated or rounded.

Selection

Narrow the range before you trial.

A catalyst trial usually fails because the question was too broad. Most inquiries can be narrowed from five product families to one or two grades with four inputs: the defect, the cure window, the working time and the acceptance test.

Dosage is a starting point, not a setting. Every production grade in the range is quoted at 0.05%–0.5% of total compound, and the correct value inside that window depends on line speed, section thickness and how much inhibitor the formulation already carries. Raising dosage to fix a colour problem or a contamination problem rarely works; those are grade decisions.

The inhibitor system is part of the same decision. Medium-to-high temperature types are dosed at 0.1%–1.0%, while the high-efficiency alkynol types are dosed at 0.01%–0.20%. If the pot life and the cure speed are set independently, the first trial can measure one variable at a time.

Concentrations from 1,000 to 20,000 PPM are supplied to order. Standard grades are quoted at six months shelf life when stored sealed at 5–15°C.

Inputs we need

Four numbers shorten the shortlist.

  • Cure temperature, and the oven profile if the line has stages
  • Line speed for coatings, or section thickness for moulded parts
  • Pot life you need between mixing and shaping
  • The acceptance test: ΔE, transmittance, roughness, yield or compression set

Send these with your current formulation and failure report. The reply states a recommended grade, platinum concentration and inhibitor pairing with starting dosages for both components.

01

Name the failure

Yellowing, haze, migration, under-cure or a failed pot. The defect decides which property the catalyst must control, and which numbers on the application page are relevant.

02

Fix the cure window

Cure temperature and line speed separate a standard grade from a high-activity or thermal grade before any formulation work begins.

03

Set the pot life

The inhibitor controls working time without slowing the hot cure. State the batch life you need, not just the cure temperature.

04

Agree the acceptance test

A measured ΔE, a transmittance reading, a roughness target or a yield figure. The test fixes the starting dosage and the reference sample.

What moves between industries

The constants, and the variables.

The chemistry does not change between these five industries; the failure mode does. That is why the same dosage range appears everywhere while the grades and inhibitors change from one page to the next.

Constant across the range

Dosage, packaging and documentation.

  • Catalyst dosage starts at 0.05%–0.5% of total compound in every application
  • Custom platinum concentrations from 1,000 to 20,000 PPM, batch COA per lot
  • Sealed 1 kg, 5 kg and 20 kg HDPE drums, stored at 5–15°C
  • TDS, SDS and RoHS / REACH statements supplied with the quotation
Varies by industry

Grade, inhibitor and cure window.

  • Anti-yellowing grades for films judged by colour after heat and UV exposure
  • High-activity and batch-controlled grades for coating lines where speed is the limit
  • High-refractive-index GZ-5 for optical systems, paired with GZ-612 or GZ-617
  • Anti-poisoning grades for potting and insulation with contaminated substrates
Next step

Not sure which application you are in?

Describe the part, the substrate and the failure. We will place it in one of these five industries, then reply with a starting grade, dosage range and the test to run first.

Technical reply within 24 hours
Evaluation samples in 5–7 days
COA, TDS and SDS on request
Custom concentration 1,000–20,000 PPM