MLCC release film: 15-minute cure, +12% yield
An MLCC release film line where surface roughness, not coater speed, set the production limit — and complete cross-link at line speed was the fix.
Each figure is tied to a measurement, and the result section below states the conditions that produced it. Field data and accelerated aging data are labelled separately, and the disclosure at the end of the case states how the data was obtained.
Measured, not claimed.
Schematic of the measurement behind this case: the same conditions, drawn to be read at a glance. The drawing is illustrative; the measured values are the ones stated in the result sections.
Where this grade is used.
Representative production images of the processes these grades are specified for. The parts shown are end applications, not test data; measured values stay in the data sections above.

The challenge.
The coater could not reach the surface roughness target of 0.2 μm at production speed because the silicone layer was not fully cross-linked when the film was wound.
Because the defect was not visible at the coater, the line had been compensating with speed. That is a capacity cost, and it does not fully solve the problem: partial cross-link can pass a visual check and still fail the roughness measurement.
The target was 0.2 μm. Roughness at that level is sensitive to both cure completeness and coat weight, so the trial held the coating weight constant while the cure chemistry was changed.
The solution.
High-activity PC series catalyst for rapid, complete cross-linking at line speed, with inhibitor dosage tuned to the coating bath life.
The trial was run on the factory line rather than in a lab coater, because line speed and winding tension are part of the cure window. Cure was assessed by rub-off and by release-force stability, with roughness measured by 3D profilometer.
Inhibitor dosage was tuned to the coating bath life so the bath stayed workable through a shift. That kept the change to one variable — the catalyst — while the working time stayed inside the line's normal window.
The result, and what produced it.
The numbers at the top of the page are the headline metrics from this case. The paragraphs here explain what produced them, with the test method and the exposure stated alongside.
Surface roughness came in at or below 0.2 μm, cure time was 15 minutes, and factory yield improved by 12%.
The yield figure is a factory gain on this line; it is not a general benchmark for other coaters or other coat weights. Cure was confirmed by rub-off and by release-force stability across the lot.
Roughness and cure time depend on coat weight, oven profile and line speed. A change in any of those is a reason to re-run the rub-off and profilometer checks.
Factory line data; roughness measured by 3D profilometer, cure assessed by rub-off and release-force stability.
Customer production case, published with permission.
The grades and the application behind this case.
Every case is tied to a catalyst grade and to an application page. The grade page carries the full specification; the application page carries the process window, dosage range and inhibitor pairing for this class of part.
| Model | Pt concentration | Viscosity | Recommended dosage |
|---|---|---|---|
| PC-11 | 1,500 PPM | 400–500 cP | 0.05%–0.5% of total compound |
| PC-12 | 5,000 PPM | 400–500 cP | 0.05%–0.5% of total compound |
| PC-16 | 4,000 PPM-1 | 400–500 cP | 0.05%–0.5% of total compound |
Open a model for packaging, shelf life, features and inhibitor pairing. Where a case names more than one grade, the solution section states which one was used in the reported trial.
Release Liners
Instant cure at several hundred metres per minute.
High-activity catalysis for electronic labels, tapes and hygiene release liners, where line speed is the production limit.
Other problems, measured the same way.
Each case is structured identically, so the challenge, solution and result can be compared across industries with the same reading discipline.
Battery pack seal: VOC compliance without losing compression set
A battery pack seal was built on a peroxide cure system. VOC emissions failed the customer's incoming specification, and the alternative addition-cure trial produced uneven cell structure and compression set above the 10% limit.
Medical LSR diaphragm: 100 steam cycles without yellowing
A respiratory valve diaphragm had to survive repeated 121°C wet-heat sterilisation without visible colour change. With the incumbent catalyst, yield after sterilisation was 82% and rejected parts were discoloured.
Mini LED encapsulation: 99.82% transmittance at 95% yield
A high-refractive-index encapsulation compound clouded when the catalyst was added, and the resulting light scattering failed the transmittance target. Yield was limited by optical rejects rather than by the dispenser.
Run a comparable trial on your own line.
Send the part, the failure and the acceptance test. We will send evaluation samples of the grade used in this case, paired with the matching inhibitor, and confirm the starting dosage for your cure window.