Case studies

Catalyst decisions, measured on production lines.

Each case below follows the same three-part structure: the challenge as the customer described it, the catalyst solution that was trialled, and the result with the test conditions that produced it. Where a number is an accelerated-aging comparison rather than a field result, the comparison is named.

Field cases

Five problems, five documented outcomes.

The cases span automotive film, medical LSR, display encapsulation, release film and battery sealing. Each card shows two headline results; open the case for the full data set, the test method and the disclosure.

New energy vehicle battery sealing

Battery pack seal: VOC compliance without losing compression set

A battery pack seal was built on a peroxide cure system. VOC emissions failed the customer's incoming specification, and the alternative addition-cure trial produced uneven cell structure and compression set above the 10% limit.

+40%cell uniformity
8%compression set, down from over 10%
Read the case
Medical device — FDA Class II end device

Medical LSR diaphragm: 100 steam cycles without yellowing

A respiratory valve diaphragm had to survive repeated 121°C wet-heat sterilisation without visible colour change. With the incumbent catalyst, yield after sterilisation was 82% and rejected parts were discoloured.

YI ≤ 1.5after 100 × 121°C cycles
98%line yield, up from 82%
Read the case
Mini LED display encapsulation

Mini LED encapsulation: 99.82% transmittance at 95% yield

A high-refractive-index encapsulation compound clouded when the catalyst was added, and the resulting light scattering failed the transmittance target. Yield was limited by optical rejects rather than by the dispenser.

99.82%light transmittance
95%production yield
Read the case
MLCC release film

MLCC release film: 15-minute cure, +12% yield

The coater could not reach the surface roughness target of 0.2 μm at production speed because the silicone layer was not fully cross-linked when the film was wound.

≤ 0.2 μmsurface roughness
15 mincure time
Read the case
Paint protection film (PPF)

PPF top coat: ΔE 0.8 where the incumbent measured 4.2

A TPU paint protection film yellowed within the warranty period under combined solar UV and engine heat. The incumbent catalyst measured ΔE 4.2 after 48 h at 85°C — visible to the eye and outside specification.

ΔE 0.8after 85°C / 48 h accelerated aging
Zero yellowingvisual assessment after aging
Read the case
Data discipline

Challenge, solution, result — and the conditions.

A catalyst result without its test conditions is not reproducible. Every case here is written the same way: the failure as it appeared in production, the grade and dosage that was trialled, the measured result, and the conditions under which it was measured.

The conditions section is what makes a number usable. A ΔE value means nothing without the ageing temperature and duration; a yield figure means nothing without the line and the part. Where a comparison catalyst was used, it was run in the same test, so the two numbers are directly comparable.

Two kinds of evidence appear here. Customer field cases come from production lines and are published with permission, without identifying the customer. Accelerated aging comparisons are internal screening runs, and they are labelled as such rather than presented as field performance.

What each case states

The minimum for a usable result.

  • The challenge, described in production terms rather than marketing terms
  • The exact grade, platinum concentration and dosage that was trialled
  • The measured result, with the measurement method named
  • The test conditions, and whether the data is field or accelerated
  • A disclosure stating how the case was obtained

If any of these is missing, the case is not published. The same rule applies to the figures quoted on product and application pages.

How to read a case

Four sections, in the same order every time.

The structure is deliberately repetitive. Once you know where to look, you can compare two cases from different industries without reading every word of the surrounding copy.

01

Challenge

What was failing on the line, in the customer's acceptance terms: a VOC specification, colour after sterilisation, transmittance, surface roughness or yellowing inside the warranty period.

02

Solution

The catalyst grade, platinum concentration and inhibitor pairing that was trialled, with any process change that went with it: vacuum defoaming, dosage adjustment or a wider cure window.

03

Result

The outcome measured the way the customer measures it: ΔE, yellowness index, transmittance, surface roughness, compression set or line yield.

04

Test conditions

Temperature, duration, instrument and reference where relevant. Field results and accelerated aging results are labelled separately, so the two are never read as the same kind of evidence.

Reading the numbers

What the data can and cannot tell you.

Three cautions that apply to every result on this site. They are the reason each case page states its conditions before it states its conclusion.

Accelerated aging is not field life

The PPF case quotes ΔE 0.8 after 48 h at 85°C against 4.2 for the incumbent tested in the same run. That is a screening comparison for formulation decisions; it is not a warranty-life prediction.

Yield figures belong to a line

The medical case moved line yield from 82% to 98%, and the MLCC case improved factory yield by 12%. Both are production numbers from a specific line, part and process: useful evidence of direction, not a guarantee elsewhere.

Identities withheld, data preserved

Customer cases are published with permission and without customer identification. The disclosure on each page states whether the data is a customer field case, an internal comparison, or a mixture of the two.

By industry

Find the process window behind a case.

Each application page carries the grades, dosage ranges and inhibitor pairing used in that industry. The cases here are the evidence; the application pages are the working instructions.

Next step

Need a case like yours?

Send the part, the substrate and the failure you are trying to remove. We will match it to the closest published case, state where that case stops being relevant, and propose a sample trial with the test to run first.

Technical reply within 24 hours
Evaluation samples in 5–7 days
COA, TDS and SDS on request
Custom concentration 1,000–20,000 PPM