Documentation for every grade, routed to the right form.
TDS, SDS and COA are issued per grade and, for the COA, per lot. This centre lists every catalyst and inhibitor model in the range, explains what each document covers, and sends each request to a technical reviewer. No static PDF is published here: a document is only useful when it matches the revision and the batch you actually receive.
One request, one revision.
A data sheet is only evidence if it belongs to the grade and revision you are evaluating. The request is reviewed by a technical engineer rather than served from an anonymous file link.
Send the request
Use the quotation or sample form and name the model and the document. If the grade is not chosen yet, describe the application, cure window and substrate instead.
We match the revision
The request is matched to the current TDS revision, the SDS language for the destination and the grade status — PC-18A, for example, is documented as an evaluation grade.
Technical review
A technical engineer checks dosage, inhibitor pairing and shelf-life conditions for the grade, so the document and the written recommendation agree.
Documents issued
TDS and SDS are emailed as the current revision within the 24-hour technical reply. The COA travels with the sample or the shipment, linked to the batch number on the drum label.
Five catalyst series, every model listed.
A TDS states the specification, dosage window, viscosity, appearance, packaging and shelf-life conditions for one grade. Each series heading below opens the series page, where the same grades are described in application context.
Standard Karstedt's Catalysts
Series overview| Model | Platinum concentration | Viscosity | Document request |
|---|---|---|---|
| PC-11 | 1,500 PPM | 400–500 cP | Request TDS / SDS |
| PC-12 | 5,000 PPM | 400–500 cP | Request TDS / SDS |
| PC-13 | 3,000 PPM | 400–500 cP | Request TDS / SDS |
| PC-14 | 4,000 PPM | 400–500 cP | Request TDS / SDS |
| PC-15 | 2,000 PPM | 400–500 cP | Request TDS / SDS |
| PC-16 | 4,000 PPM-1 | 400–500 cP | Request TDS / SDS |
High-Activity & Anti-Poisoning Catalysts
Series overview| Model | Platinum concentration | Viscosity | Document request |
|---|---|---|---|
| PC-41 | 1,500 PPM | 400–500 cP | Request TDS / SDS |
| PC-43 | 3,000 PPM | 400–500 cP | Request TDS / SDS |
| PC-44 | 4,000 PPM | 400–500 cP | Request TDS / SDS |
| PC-45 | 2,000 PPM | 400–500 cP | Request TDS / SDS |
| PC-46 | 4,000 PPM-1 | 400–500 cP | Request TDS / SDS |
Thermal Stability & Anti-Yellowing Catalysts
Series overview| Model | Platinum concentration | Viscosity | Document request |
|---|---|---|---|
| PC-42 | 5,000 PPM | 300–500 cP | Request TDS / SDS |
| PC-50 | Custom (1,000–20,000 PPM) | 5–50 cP | Request TDS / SDS |
| PC-51 | Custom (1,000–20,000 PPM) | 5–50 cP | Request TDS / SDS |
Advanced Anti-Poisoning Catalysts
Series overview| Model | Platinum concentration | Viscosity | Document request |
|---|---|---|---|
| PC-18B | Custom (1,000–20,000 PPM) | 400–500 cP | Request TDS / SDS |
| PC-18AR&D · sample | Custom (1,000–20,000 PPM) | 400–500 cP | Request TDS / SDS |
Optical Grade High-Refractive-Index Catalysts
Series overview| Model | Platinum concentration | Viscosity | Document request |
|---|---|---|---|
| GZ-5 | Custom (1,000–20,000 PPM) | 400–800 cP | Request TDS / SDS |
PC-18A is under final R&D: documentation is issued for evaluation quantities, and commercial supply is not yet committed. All other grades are available now.
Seven inhibitors, documented the same way.
Inhibitor data sheets cover the cure window, appearance, dosage range, pairing recommendations and pot-life behaviour. They are issued with the catalyst data when a trial is set up, because the two components are specified together.
| Model | Cure window | Dosage | Document request |
|---|---|---|---|
| PC-611 | Medium-to-high temperature | 0.1%–1.0% | Request TDS / SDS |
| PC-612 | Medium-to-high temperature | 0.1%–1.0% | Request TDS / SDS |
| PC-613 | Ambient / low temperature | 0.1%–1.0% | Request TDS / SDS |
| PC-614 | Ambient / low temperature | 0.1%–1.0% | Request TDS / SDS |
| PC-617 | High efficiency, non-hazardous | 0.01%–0.20% | Request TDS / SDS |
| GZ-612 | High-RI systems | 0.1%–1.0% | Request TDS / SDS |
| GZ-617 | High-RI systems | 0.01%–0.20% | Request TDS / SDS |
SDS: issued for the grade and the destination.
The SDS carries the hazard classification, handling precautions, storage conditions, first-aid measures, transport information and disposal guidance for the grade as supplied.
It is not published as a fixed file because two variables change the document: the platinum concentration — custom grades from 1,000 to 20,000 PPM are made to order — and the language required for the destination and for internal hazard communication. A statement accurate for a 1,500 PPM grade should not be reused for a 20,000 PPM custom batch.
- Classification stated for the concentration supplied
- Storage at 5–15°C, sealed, with the shelf-life statement included
- Transport documentation aligned with the shipping method
- Issued in the language requested for the destination
COA: one batch, one certificate.
Every batch is issued with a COA that states the measured platinum content and the lot data. The batch number on the drum label links to that certificate, so a claim raised three shipments later can be checked against the material that was actually delivered.
The COA covers the catalyst as supplied. It does not certify a cured part, a formulation or a device — those depend on everything else in the compound and on the process. For a sample, the COA for the lot is included so the evaluation starts from a traceable material.
Questions about documents.
Why is there no PDF download button?
Because documents are revision- and lot-controlled. A file served from a page can be months out of date or belong to a different concentration. Instead, the request is matched to the grade you are evaluating and returned as the current revision.
How quickly are documents issued?
The technical reply arrives within 24 hours of a request made on a business day. TDS and SDS are attached to the quotation response; the COA follows the sample or the shipment, because it belongs to the batch.
Can I receive a TDS before choosing a grade?
Yes. Describe the application, cure temperature, substrate and the problem you are solving, and the technical reply will recommend a starting grade with its TDS and SDS attached.
Do I need an NDA to request documents?
No. Documents are issued for evaluation and procurement. A mutual NDA is available if you want to share formulation detail beyond the process data the forms ask for.
Three details that get the right document first time.
- The model — or the application and cure window if the model is not chosen
- The destination country, for the SDS language and transport information
- The document you need: TDS, SDS, COA, or the RoHS / REACH statement
If you also need the compliance statement, say so in the same message. Compliance declarations are handled through the compliance page and can travel with the same response.
Request the document set for your grade.
Send the model, the destination and the documents you need. The reply includes the current TDS and SDS revision, the compliance statement where applicable, and the sample or quotation path for a COA.